TABLE OF CONTENTSJOB SPECIFICATION SHEET ...1EQUIPMENT CONFIGURATION ...
10Level IV Viewing History - H ValuesHistorical information can be viewed by pressing the SET and DOWN buttons simultaneously, with the ProSense contr
11DISINFECTION OF WATER CONDITIONING SYSTEMSThe materials of construction in the modern water conditioning system will not support bacterial growth, n
12WIRING DIAGRAMSConnecting the ProSense Twin Alternating or Parallel ControllerThe twin sensor and extension cables are used for twin unit parallel a
13POWERHEAD ASSEMBLYItem No. QTY Part No. Description 1 ...1 ... 15131 ...Backplate, 9000 2 ...2 ...
14ProSense CONTROL VALVE ASSEMBLYItem No. QTY Part No. Description 1 ...1 ... 40688 ...Valve Body Assy, ProSense 2
15Item No. QTY Part No. Description 1 ...4 ... 40678 ...Ring, ProSense, Yoke Retainer 2 ...4 ... 13
163/4" METER ASSEMBLYItem No. QTY Part No. Description 1 ...1 ... 14613 ...Flow Straightener 2 ...
171" METER ASSEMBLYItem No. QTY Part No. Description 1 ... 4 ... 12112 ...Screw, Hex Hd Mach 10-24 x 1/2 2 ...
18Item No. QTY Part No. Description 1 ...1 ... 17290 ...By-Pass Body, 3/4” 1 ... 17290NP ... By-Pass Bo
19Item No. QTY Part No. Description 1 ...2 ... 13305 ...O-ring, -119 2 ...2 ... 13255 ...
2SAFETY INFORMATIONThis water conditioner’s control valve conforms to UL/CE Standards. Generic valves were tested and certied for compliance as veri
20PROBE KITItem No. QTY Part No. Description 1 ...1 ... 30212618 ...Probe/Cable/Clips Kit1
21Problem Cause Correction1. Water conditioner fails to regenerate. A. Electrical service to unit has been interruptedA. Assure permanent electrical
22ProSense ControllerProblem Cause SolutionERR 1 is displayed. Program settings have been corrupted. Press any key and reprogram Level I settings.ERR
23ProSense METER FLOW DATA
24ProSense INJECTOR FLOW DATA (1600 SERIES INJECTORS)
25PROSENSE CONTROL VALVE DIMENSIONS
26WATER CONDITIONER FLOW DIAGRAMSIn Service Position Tanks Switching Position(Meter Initiated Regeneration)Backwash Position Brine Draw PositionIn Ser
27Slow Rinse Position Rapid Rinse PositionBrine Tank Fill PositionWATER CONDITIONER FLOW DIAGRAMS continued
28Brine Line Flow Controls (ProSense):60022-12 ...BLFC, .125 GPM, 5000/5600/9000/ProSense60022-50 ...BLFC, .50 GPM,
29SERVICE ASSEMBLIES continued
3Valve to Tank Installation Instructions1. Spin the valve onto the tank, ensuring the threads are not cross-threaded.NOTE: The main control valve and
IOM-WQ-PROSENSE 1248 EDP# 2915953 © 2013 WattsUSA: Tel. (800) 659-8400 • www.watts.com Canada: Tel. (888) 208-8927 • www.wattscanada.caA Watts W
4CONTROLLER FEATURESDisplay Icons & CursorsTime/DayRegeneration TimeSalt AmountCapacitySU MO TU WE THFRSA DAYSHardnessg/LPMMINKGx2x100PHCLbs/ft321
5Keypad - Buttons1 2 3 4Figure 5 1. SET. Used to accept a setting that normally becomes stored in memory. Also used together with the arrow buttons.2
6Time/DayRegeneration TimeSalt AmountSU MO TU WE TH FR SA DAYSCapacitySalt AmountSU MO TU WE TH FR SA DAYSCapacitySalt AmountSU MO TU WE TH FR SA DAYS
7PROGRAMMING MODE continuedIn Service DisplayTime & DayRegen Time & DaySalt AmountSU MO TU WE TH FR SA DAYSCapacityTime & DayRegen Time &a
8Level II Programming - P ValuesLevel II Programming parameters can be adjusted to ne-tune the conditioner's operation. The parameters are acces
9PROGRAMMING MODE continuedLevel III Cycle Programming - C ValuesSeveral Level III program parameters can be adjusted to ne-tune valve operation for